Fieldbus systemseries MVE |
|
|||||||||||||||||||
The fieldbus system of the MVE series system allows the connection and control of valves and other inputs and outputs using the EtherNet / IP protocol. Up to 23 channels are available in one set for the control of associated valves (MVSY 100 and MVSY 156 series) as well as up to 8 input and output units, with 8 inputs or 8 outputs in each unit. It is therefore easy to connect and control the island with valves and send back to the control system, for example, the states of the end position sensors. The configuration can be modified using a web browser or using a configuration program on a computer. Both the main and I/O units have LEDs that inform the user of the status.
|
System description
Features
- compatible protocol EtherNet/IP
- max. 8 units can be connected of I/O
- wiring time and labor costs can be reduces
- short / open circuit detection function, the location of error can be idnetified
- counter function, it is possible to ascertain the maintenance period and identify the parts that require maintenance
- web server function, enable status checking and parameter setting by using web browser
System diagram
|
Compatible topologies
In addition to the general star type, it is available for linear and ring topologies:
Linear type |
Ring type |
Web server function
Using general web browsers, such as IE, Google Chrome which enables status check and parameter settings. Operation and maintenance of the system can be performed efficiently.
MVE 1 ~ 4
can be accessed
via a web browser.:
|
Accessories
|