4/2, 5/2 a 5/3 function valves - valve properties and selection table
Series | Port size | Flow capacity [Nl/min] |
Working |
Connection* | Voltage | Connector type | |||
1* | 2* | 3* | DC [V] | AC [V] | |||||
K1 | G1/8" | 1000 | 0,15 to 1,0 (vacuum to 2,1) |
![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
K2 | G1/4", G3/8" | 1700 | 0,15 to 1,0 (vacuum to 2,1) |
![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
K3 | G1/2" | 3500 | 0,15 to 1,0 (vacuum to 2,1) |
![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
MVSC** | G1/4", G3/8", G1/2" | 980 to 2730 | 0,2 to 0,8 | ![]() |
![]() |
![]() |
12, 24 | 24, 110, 230 | 22 |
MVSE-260/300/500 | G1/4", G3/8", G1/2" | 980 to 2180 | 0,2 to 1,2 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
MVSE-510/600 | G1/2", G3/4", G1" | 3400 to 4830 | 0,2 to 0,7 | ![]() |
![]() |
![]() |
24 | 110, 230 | DIN 43650 A |
MVSN | NAMUR | 1630 to 1905 | 0,2 to 0,8 | ![]() |
![]() |
![]() |
24 | 24, 230 | 22 |
MVSY | M5, G1/8", G1/4" | 200 to 760 | 0,15 to 0,7 | ![]() |
![]() |
![]() |
6, 12, 24 | 230 | special, with cable |
L01 | G1/8" | 200 | vacuum to 1,0 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
L1** | G1/8", G1/4" | 1000 | 0,1 to 1,0 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
L2** | G1/4", G3/8" | 1700 | 0,1 to 1,0 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
KI ISO 2 Compact | ISO 2 - G3/8" | 2800 | 0,15 to 1,0(2,1) | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | 22 |
ISO 1 Compact | ISO 1 - G1/4" | 1400 | 0,1 to 1,6 | ![]() |
![]() |
![]() |
12, 24 | 24, 110, 230 | DIN 43650 A, 22 |
ISO 1** indirect act. |
ISO 1 - G1/4" | 1200 | 0,1 to 1,6 | ![]() |
![]() |
![]() |
12, 24 | 24, 110, 230 | DIN 43650 A, 22 |
ISO 1** direct act. | ISO 1 - G1/4" | 1200 | vacuum to 2,1 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | DIN 43650 A |
ISO 2 Compact | ISO 2 - G3/8" | 2800 | 0,1 to 1,6 | ![]() |
![]() |
![]() |
12, 24 | 24, 110, 230 | DIN 43650 A, 22 |
ISO 2** indirect act. | ISO 2 - G3/8" | 1700 | 0,1 to 1,6 | ![]() |
![]() |
![]() |
12, 24 | 24, 110, 230 | DIN 43650 A, 22 |
ISO 2** direct act. | ISO 2 - G3/8" | 1700 | vacuum to 2,1 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | DIN 43650 A |
ISO 3 Compact | ISO 3 - G1/2" | 4200 | 0,1 to 1,6 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | DIN 43650 A, 22 |
ISO 3** indirect act. | ISO 3 - G1/2" | 4300 | 0,1 to 1,6 | ![]() |
![]() |
![]() |
12, 24 | 24, 110, 230 | DIN 43650 A, 22 |
ISO 3** direct act. | ISO 3 - G1/2" | 4300 | vacuum to 2,1 | ![]() |
![]() |
![]() |
24 | 24, 110, 230 | DIN 43650 A |
High-flow | G1", G1 1/2" | 16000 to 28000 | 0,2 to 0,7 | ![]() |
![]() |
![]() |
24 | 24, 230 | DIN 43650 A |
*) Valve connection: 1 - in-line 2 - individual base 3 - manifold block |
**) Valves are available with explosion proof solenoids too. |
***) Working pressure may be higher / lower, when option coils and external pilot supply is used | Notice: due to spool and sleeve assembly, minor leakage may occur in 5/3 with closed center. If you need to ensure 100% leakproof, it is necessary to use valve with rubber packed spool. |