List of changes of PDF catalogue of pneumatic components No. 12
Situation on the date 14. May 2012 - changes are related to the 1st issue of catalogue No. 12. Catalogue No. 12 can be downloaded from the archive. You can download the full actual PDF catalogue here.
Page | Date of change | Description | Issue |
2-2 | 2.9.2011 | Added cylinder diameter 125 mm | 1* |
2-16 | 14.5.2012 | Option 11 in combination with magnetic piston causes different dimensions | 1* |
2-18 | 23.5.2011 | Options No. 05, 10, 11 and 17 are no longer valid as a standard, but they are available as cylinder tu customer's request | 1* |
2-20 | 1.6.2010 | Added infoo about wiping ring material | 1* |
2-37 | 7.9.2010 | Graphs of capacity for using as a lifter was corrected | 1* |
2-37 | 5.1.2012 | Graphs of capacity for using as a lifter was corrected | 1* |
4-12 | 2.9.2011 | Corrected values of trunnion mounting (order code 2101...): dia. 63/80: value B1, dial. 160/200: values B, C and D | 1* |
4-16 | 1.6.2010 | Column header MD corrected to FB for foot mounting for rodless cylinders | 1* |
5-8 | 27.1.2012 | Solenoid actuated valves series J are not available form today. They can be replaced by valves series L1/L2 with fixed coil or by valves series MVSC. Archive datasheet is available here. | 1* |
5-10 | 28.2.2011 | Corrected thread of external pressure supply port for series L2 | 1* |
5-10 | 5.1.2012 | Solenoid actuated valves series L1/L2 with exchangeable coils are not available form today. They can be replaced by valves series L1/L2 with fixed coil. Archive datasheet is available here. | 1* |
5-23 | 1.6.2010 | Voltage 24V 50Hz isn't available | 1* |
5-23 | 7.9.2010 | Order codes for connectors witl longer cable was added |
1* |
6-5 | 10.4.2012 | Added informations about mounting nuts |
1* |
6-7 | 12.10.2010 | Corrected pressure range and graph, operating instruction and CE certificate was added (www only) |
1* |
8-2 | 12.10.2010 | Corrected labels on grafps (values MPa) |
1* |
8-4 | 12.10.2010 | Corrected labels on grafps (values MPa) | 1* |
8-4 | 25.8.2010 | Value of max. inlet pressure was corrected | 1* |
8-5 | 25.8.2010 | FRL unit series MACC300 - added info about semi-automatic drain | 1* |
8-6 | 25.8.2010 | Information about primary pressure was corrected for series MAF300 and MAF500 | 1* |
8-8, 8-9 | 12.10.2010 | Corrected labels on grafps (values MPa) | 1* |
8-10 | 12.10.2010 | Corrected labels on grafps (values MPa) | 1* |
8-10 | 21.12.2010 | Corrected weight of MAFR500 unit | 1* |
8-13 | 9.8.2010 | Order codes of diverter blocks was corrected | 1* |
8-13 | 28.2.2011 | Corrected order codes for spare filter elements for series MACC300 | 1* |
9-4 | 2.9.2011 | Corrected values of constant and emergency load of type 1,5 | 1* |
10-6 | 9.5.2011 | Corrected order code of straight connector reduced 12-10 | 1* |
10-6 | 10.4.2012 | X connector push-on fitting 4/2 (N354-004-000) are not available for the future | 1* |
10-11 | 28.2.2011 | Corrected order code of PU tube 12/8 | 1* |
List of changes between printed catalogues No. 12 and No. 11
Page in catalogue No. 12 |
Page in catalogue No. 11 |
Description | Type of change |
- | 5-34 | Valves series C13P - product discontinued |
Discontinued |
- | 6-5 | Valves series Z22 - product discontinued | Discontinued |
- | 8-5 až 8-17 | FRL unit series FlexiBlok - product discontinued | Discontinued |
- | 8-19 až 8-21 | FRL unit series HF - product discontinued | Discontinued |
- | 8-23 | Pressure switch series PS24 - product discontinued | Discontinued |
- | 8-23 | Digital pressure switch series DPS - product discontinued | Discontinued |
1-2, 1-3 | - | Two pages with news in catalogue, info about items for explosive area | New |
1-4 | 1-2 | Info about our webpage |
Amending |
1-5 | 1-3 | School license of AutomSim Premium | Amending |
1-8 | 1-6 | Change of text regarding the FRL unit maintaining | Correction |
1-11 | 1-9 | Correction of formula for Wkg for mass without driving power | Correction |
2-* | 2-* | The valve bracket and proportional proximity switch was added into the picture of available accessories, where it is relevant | Amending |
2-* | 2-* | The material option No. 14 was added for all cylinders | Amending |
2-4 | 2-4 | Added info anout option No. 5 | Amending |
2-14 | 2-14 | Added equipment No. 05 and 15 | Amending |
2-16 | 2-16 | Added equipment No. 05, 15, 55 and 65 | Amending |
2-18, 2-19 | - | Cylinders with pressed-in tube |
New |
2-20 až 2-23 | - | Anti-corrosive, hygienic clean cylinders |
New |
2-27 | 2-21 | Correction of values in column D - guiding rod diameter |
Correction |
2-30 to 2-35 | 2-24 to 2-27 | Rodless cylinders - change of order codes, added VL1 type, correction of dimensions | Change |
2-36 | - | Cylinders series MCGB double guide |
New |
2-40 | - | Cylinders series MCGD double guide |
New |
2-42 | - | Cylinders series MCDA double piston | New |
2-44 | - | Cylinders series MCDB double piston | New |
2-50 | - | Support series MCSS double piston |
New |
2-51 | - | Stopper cylinders series MSBD, MSBR and MSBS | New |
2-52 | 2-28 | Added info about option No. 5, correction of text - cylinders are without cushioning | Amending Correction |
2-58 | 2-34 | Options No. 11 and 15 are not available for this cylinder | Correction |
2-62 | 2-38 | Change of stroke of knocker dia. 32 from 60 to 45 mm | Change |
2-66 | - | Air gun |
New |
2-68 | - | Clamps series MTAD and MTAS | New |
2-69 | - | Clamps series MCKA | New |
2-70 | - | Angular grippers series MCHA and parallel grippers series MCHB | New |
2-71 | - | Three jaws gripper series MCGH2 | New |
2-72 | - | Pneumatic-hydraulic power cylinders seriesMHPD | New |
3-10 | - | Proximity switches series RCE and RNE for cylinders series M* | New |
3-11 | - | Technical information - rules for using proximity switches |
New |
3-12 | - | Proportional switch series MPS | New |
4-3 | 4-3 | Piston rod eye - column L was deleted, change of the picture | Change |
4-8 | 4-8 | Swivel flange - correction of dimensions J, K, L, M, R for dia. 32 and 40 mm | Correction |
4-9 | - | Narrow swivel flange and rectangular swivel flange - both as mate for swivel flange with spherical bearing | New |
4-12 | 4-11 | Trunnion mounting for cyl. dia 320 mm | Amending |
4-13, 4-14 | - | Accessories made form stainless steel for (not only) anti-corrosive hygienic clean cylinders | New |
4-15 | 4-12 | Mounting plate for rodless cyl. - correction of dimensions | Correction |
4-16 | 4-13 | Foot mounting for rodless cyl. - correction of dimensions | Correction |
4-16 | 4-13 | Floating flange for rodless cyl. - correction of dimensions | Correction |
4-17 | - | Connections for rodless cyl. | New |
4-18 | 4-14 | Added info about the materials |
Amending |
4-22 | - | Valve bracket |
New |
5-2 | 5-2 | Changes in the tabs for cosing the valve - amending of new series | Change |
5-4 | 5-4 | Added valves series MVSC 5/3 with exhaust centre position and with pressure centre position, info about manifolds with internal wiring, added manifolds | New Amending |
5-6 | - | Valve series MVSE - G1/2", G3/4", G1" | New |
5-23 | - | Valve series MVSY - M5, G1/8", G1/4" | New |
5-36 | - | High flow valve series - G1" and G1 1/2" | New |
5-42 | - | Valve series MVDC - 2/2 and 3/2 | New |
6-4 | 6-4 | Valve series MVHB - added series 300, all series: added function PM/PSPM - pressure centre position | New Amending |
6-5 | 6-6 | Valve series MVHC - added series 200 and 400, all series: added function exhaust centre position | New Amending |
6-7 | - | Two hand safety valve with CE certification |
New |
6-12 | 6-12 | Valve series MVFA - added functions 3/2 NC and NO with or without locking | Amending |
6-16 | - | High flow valve series - G1" and G1 1/2" | New |
8-2 | - | FRL unit series MACP300 - G1/4" and G3/8" | New |
8-3 | 8-2 | FRL unit series MACP401 - added info about semi-automatic drain | Amending |
8-4 | - | FRL unit series MACP500 - G3/4" and G1" | New |
8-6 | - | Filters series MAF300, MAF401 and MAF500 | New |
8-7 | - | Coalescing filters series MAF401 | New |
8-8 | 8-4 | Pressure regulators series MAR200 and MAR300 - added MAR300 G1/4" and G3/8", correction of weights | Amending Correction |
8-9 | - | Pressure regulators series MAR401 and MAR500 | New |
8-10 | - | Particular filters series MAFR300, MAFR401 and MAFR500 | New |
8-12 | - | Lubricator MAL300, MAL401 and MAL500 | New |
8-13 | - | Spare bowls and filter elements for FRL units series MA* | New |
8-13 | - | Diverter blocks for FRL units series MACP300 and MACP401 | New |
8-13 | 8-4 | Offer of gauges PPG was extended |
New Amending |
8-14 | 8-22 | Correction of order codes of pressure switches series PS31 2-5MPa | Correction |
8-15 | - | Digital pressure switch series MP25, 2 PNP outputs+1 analog, G1/8" | New |
9-* | 9-* | Corrected text regarding type and characteristics for all shock absorbers | Correction |
9-2 | 9-2 | Hydraulic shock absorber - added NC-E0,1, correction of weight for type 0,2, correction of dimensions |
Amending Correction |
9-3 | 9-3 | Hydraulic shock absorber - correction of dimensions | Correction |
9-4 | 9-4 | Hydraulic shock absorber - correction of dimensions A and F, weight of type 1,25x2, corrected table with energy absorption and effective mass | Correction |
9-5 | 9-5 | Hydraulic shock absorber - correction of dimensions E, E1 | Correction |
9-6 | 9-6 | Hydraulic shock absorber - correction of dimension C of rectangular flange, A, B and C of square flange, all dimensions of stop limit nut | Correction |
9-7 | 9-7 | Hydraulic speed control - correction of dimension B of V60, correction of width of flange of V40 and bigger | Correction |
10-11 | - | Spiral PU tubes with straight ends | New |
10-11 | 10-11 | Tubes PU - added dimensions 10/6,5 and 12/8 | Amending |
10-14 | - | Rotary couplings |
New |