Solenoid actuated valves
series ISO 5599/1 - indirect solenoid actuated |
|
The most common type of air pilot solenoid actuated valve, which is designed for use with sub-bases. Coil of air pilot actuated valve can be turned so that it will serve the purpose. Valves can be use as standalone with individual base or they can be mounted on manifolds. Valves series ISO 5599/1 contains spool and sleeve assembly, which guarantee long lifetime of valve. |
Order codes | Technical data |
Dimensions | Connectors | Coils | Data sheet (PDF) | Technical information |
Bases and manifolds |
Connection dimensions |
Technical data
Series | ISO 1 | ISO 2 | ISO 3 |
Flow capacity [Nl/min] |
1200 |
1700 | 4300 |
Working pressure [MPa] | 0,1 to 1,0 , or 0,1 to 1,6 (for pilot type 190) (vacuum to 1,6 MPa when external air pilot supply type 190 is used) |
||
Pilot pressure range [MPa] | 0,1 to 1,0 , or 0,1 to 1,6 (for pilot type 190) | ||
Power input for pilot type 189 [W, VA] | 2,5W for DC voltage, 6VA inrush and 3,5VA hold for AC voltage | ||
Power input for pilot type 190 [W, VA] | 3W for DC voltage, 9VA inrush and 4VA hold for AC voltage | ||
Response time energize / de-energize [ms] |
20 / 32 |
20 / 32 | 15 / 36 |
Temperature range [°C] | ambient temperature -20 to +80 |
Conversion of internal to external air pilot supply of valve series ISO 5599/1
External air pilot supply is used, when air supply pressure is lower than 0,1 MPa (1 bar) as well as for vacuum and or if another medium than compressed air is used. It is necessary to order valve which is already prepared for this feature or change standard setting (when air pilot supply is drawed from valve supply port 1) in that cases. If supply air is piped to ports 3 or 5, the valve must be converted too. Please find the correct orientation of gasket for your usage in the table below. This process is valid only for valves series ISO 5599/1.
When converting pilot supply, please proceed as follows:
1) Remove the end caps
2) Remove gasket and position it so that the tab points toward the appropriate port number
3) Check gasket instalation and install end caps
4) If it is necessary, convert second side of valve too
Picture shows the gasket tab orientation for various cases:
|
|